Wednesday, May 26, 2010

1994-1997 Cadillac Seville Revised HVAC Blower Motor Installation Procedures

The intent of this bulletin is to provide technicians information regarding the proper installation of the Heating, Ventilation and Air Conditioning (HVAC) Module blower motor (with impeller) assembly.
The current available HVAC Module blower motor for the above listed vehicles can be identified by the three mounting holes (1). The original equipment blower motor had five mounting holes.
In order to avoid confusion and ensure a high level of customer satisfaction, when replacing an HVAC Module blower motor, refer to this bulletin for the appropriate procedure.

DeVille-HVAC Blower Motor
Caution
Before servicing any electrical component, the ignition key must be in the OFF or LOCK position and all electrical loads must be OFF, unless instructed otherwise in these procedures. If a tool or equipment could easily come in contact with a live exposed electrical terminal, also disconnect the negative battery cable. Failure to follow these precautions may cause personal injury and/or damage to the vehicle or its components.

Removal Procedure
1. Disconnect the negative battery cable.
2. Remove the cross-car brace. Refer to Brace Replacement-Cross Vehicle in the Body Front End sub-section of the Service Manual or SI document #369605.
3. Disconnect and position the ignition control module assembly out of the way. Refer to Ignition Control Module Replacement in the Engine Controls sub-section of the Service Manual or SI document #189202.
4. Position the cross-car harness out of the way.
5. Remove the solenoid purge valve. Refer to Evaporative Emission (EVAP) Canister Purge Solenoid Valve Replacement in the Engine Controls Sub-section of the Service Manual or SI document #411822.
6. Remove the blower motor.
- Disconnect connector from the blower motor.
- Remove the blower motor screws (either 3 or 5 screws).
- Remove the blower motor from the HVAC Module